TT.Mk1 Onboard Diagnostics via HVAC Display
From QuattroWorld Wiki
Back to 2000-2005 (Mk1)
Submitted and Entered by: MCPaudiTT
You can use the display on the HVAC unit to display various parameters. Not all of the following list works on every VAG product, but this is a good "starting point" to use.
Accessing On-Board Diagnostic codes:
1. Press and hold the recirculation button.
2. Press the manual flow control up arrow. The display should show "1 C".
3. Press the temperature up ("+") or down ("-") buttons to select a code number from the list below.
4. Press the recirculation button again to "enter" the code selection. The value for the chosen parameter should appear in the HVAC display.
5. Press the temperature up or down button again to display another code.
NOTE: Not all elements in this list function on all models or markets.
| Code | Parameter |
|---|---|
| 1 | System malfunction - displayed as a Diagnostic Trouble Code (DTC) |
| 2 | Digital value of Interior Temperature Sensor, in Headliner (G 86) |
| 3 | Digital value of Interior Temperature Sensor, in Instrument Panel (G 56) |
| 4 | Digital value of Fresh Air Intake Duct Temperature Sensor (G 89) |
| 5 | Digital value of Outside Air (Ambient) Temperature Sensor (G 17), front |
| 6 | Digital value of Outside Air (Ambient) Temperature Sensor |
| 7 | Digital value of Ambient Temperature Sensor At Fresh Air Blower (G 109) |
| 8 | Digital value of Temperature Regulator Flap Motor Potentiometer (G 92) |
| 9 | Delta value of Temperature Regulator Flap |
| 10 | Non-corrected specified value of Temperature Regulator Flap |
| 11 | Digital value of Central Flap Motor Potentiometer (G 112) |
| 12 | Specified value of Central Flap |
| 13 | Digital value of Footwell/Defroster Flap Motor Potentiometer (G 114) |
| 14 | Specified value of Footwell/Defroster Flap |
| 15 | Digital value of Air Flow Flap Motor Potentiometer (G 113) |
| 16 | Specified value of Air Flow Flap |
| 17 | Vehicle Speed (km/h) |
| 18 | Actual Air Blower voltage (Volts) |
| 19 | Specified Fresh Air Blower voltage (Volts) |
| 20 | A/C Compressor (A/C Clutch) voltage (Volts) |
| 21 | Number of low voltage occurrences, non-transient |
| 22 | Cycle condition of A/C Refrigerant High Pressure Switch (F 118) |
| 23 | Cyclings of the A/C Refrigerant High Pressure Switch (F 118) |
| 24 | Cyclings of the switches, absolute non-fluctuating |
| 25 | Analog/Digital value, Kick-Down Switch |
| 26 | Analog/Digital value, Engine Coolant Temperature (ECT) Warning Light |
| 27 | Engine Speed (RPM) |
| 28 | N/A |
| 29 | A/C Compressor speed in rpm (Equals Engine Speed x 1.28) |
| 30 | Software version |
| 31 | N/A |
| 32 | Potentiometer malfunction counter, Temperature Regulator Flap |
| 33 | Potentiometer malfunction counter, Central Flap |
| 34 | Potentiometer malfunction counter, Footwell/Defroster Flap |
| 35 | Potentiometer malfunction counter, Air Flow Map |
| 36 | Feedback value, cold end-stop, Temperature Regulator Flap Motor Potentiometer (G 92) |
| 37 | Feedback value, hot end-stop, Temperature Regulator Flap Motor Potentiometer (G 92), max.
stop |
| 38 | Feedback value, cold end-stop, Central Flap Motor Potentiometer (G 112) |
| 39 | Feedback value, hot end-stop, Central Flap Motor Potentiometer (G 112) |
| 40 | Feedback value, cold end-stop, Footwell/Defroster Flap Motor Potentiometer (G114) |
| 41 | Feedback value, hot end-stop, Footwell/Defroster Flap Motor Potentiometer (G114) |
| 42 | Feedback value, cold end-stop, Air Flow Map Motor Potentiometer (G 113) |
| 43 | Feedback value, hot end-stop, Air Flow Map Motor Potentiometer (G 113) |
| 44 | Vehicle operation cycle counter |
| 45 | Calculated interior temperature (internal software, in digits) |
| 46 | Outside (ambient) temperature, filtered, for regulation (internal software) |
| 47 | Outside (ambient) temperature, unfiltered, (internal software, in deg C) |
| 48 | Outside (ambient) temperature, unfiltered, (in digits) |
| 49 | Real Time coolant temp in deg C |
| 50 | Standing time (in minutes) |
| 51 | Engine Coolant Temperature (ECT) in deg C, "smoothed" version of 49 |
| 52 | Graphics channel 1 - A/C compressor switch-off conditions are identified by illuminated
segments of the "88.8" display. |
| 53 | Graphics channel 2 - Climate system electrical outputs are identified by illuminated segments of the "88.8" display. |
| 54 | Control characteristics |
| 55 | Outside (ambient) temperature, in deg C or deg F depending on setting on A/C control head |
| 56 | Temperature in deg C, from Interior Temperature Sensor, in Headliner (G 86) |
| 57 | Temperature in deg C, from Interior Temperature Sensor, in Instrument Panel (G 56) |
| 58 | Temperature in deg C, from Fresh Air Intake Duct Temperature Sensor (G 89) |
| 59 | Temperature in deg C, from Outside Air (Ambient) Temperature Sensor (G 17), front |
| 60 | Temperature in deg C, from Ambient Temperature Sensor At Fresh Air Blower (G 109) |
| 61 | Software version (latest) |
| 86 | Display Check (All Segments of Climate Control display light up |
Back to 2000-2005 (Mk1)